Public address systems in buildings like airports, railway stations, shopping centers or concert halls have to clearly inform persons in danger about escape information and directions in case of an emergency. The XL2 Analyzer measures the speech intelligibility of emergency systems in accordance with the standard IEC 60268-16:2011 (edition V4.0).
The XL2 displays the measurement results as STI or as CIS results, accompanied by the individual levels and modulation indices of the seven octave bands. The measurement results are acquired from the dedicated STIPA test signal.
The XL2 Analyzer measures the speech intelligibility according to the latest revision of standard IEC 60268-16:2011 (edition 4) and older editions. It includes ambient noise correction and automated averaging of measurements. The XL2 displays the measurement results as STI or as CIS results, accompanied by the individual levels and modulation indices of the seven octave bands.
The measurement results are acquired from the dedicated STIPA test signal source:
•NTi Audio TalkBox, acoustic signal generator, required for audio systems with voice microphones, thus measuring the complete signal chain
•Minirator MR-PRO, test signal generator, required for audio systems with line inputs
•STIPA Test CD (included)